Solar Power Plants in Tamilnadu

Trusted partner for
fulfilling sustainability goals

Solar Power Plants in Tamil Nadu

In alignment with our mission to provide dependable clean energy solutions to our partners, we first set foot in Tamil Nadu in 2014. Since then, we have installed 39 solar power plants in the state with a total constructed capacity of 28,036,125 kW and abated 26,915 tonnes of CO2 per annum. We have provided green energy to clients in the state across diverse sectors – Auto, Auto ancillaries, Education, Government, and Engineering/Capital Goods(Manufacturing).

Below are few of the projects by CleanMax in Tamil Nadu

Statewise Projects

Project size: 6,000 kWp
Roof type: Metal + RCC + Ground Mount
Module type: Polycrystalline
Inverter type: String
Industry type: Infrastructure
Commissioned on: 2018
CO2 abated annually: 8,640 Tonnes
Equivalent to planting: 142,864 trees
View Photos

6,000 kWp, RCC+Metal Rooftop and Ground Mount Installation

Tamil Nadu,  Chennai

Project size: 351 kWp
Roof type: RCC Rooftop
Module type: Polycrystalline
Inverter type: String
Industry type: Education
Commissioned on: 2018
CO2 abated annually: 505 Tonnes
Equivalent to planting: 8,358 trees
View Photos

351 kWp, RCC Rooftop Installation

Tamil Nadu,  Chennai

Solar Power Plants In Tamilnadu in India
Project size: 648 kWp
Roof type: Metal Rooftop
Module type: Polycrystalline
Inverter type: String
Industry type: Auto & Auto ancillaries
Commissioned on: 2017
CO2 abated annually: 933 Tonnes
Equivalent to planting: 15,429 trees
View Photos

648 kWp, Metal Rooftop Installation

Tamil Nadu,  Chennai

Solar Power Plants In Tamilnadu in India
Project size: 582 kWp
Roof type: RCC Rooftop
Module type: Polycrystalline
Inverter type: String
Industry type: Real Estate
Commissioned on: 2015
CO2 abated annually: 838 Tonnes
Equivalent to planting: 13,858 trees
View Photos

582 kWp, RCC Rooftop Installation

Tamil Nadu,  Chennai

Solar Power Plants In Tamilnadu in India
Project size: 98 kWp
Roof type: Metal Rooftop
Module type: Polycrystalline
Inverter type: String
Industry type: Auto & Auto ancillaries
Commissioned on: 2015
CO2 abated annually: 141 Tonnes
Equivalent to planting: 2,333 trees
View Photos

98 kWp, Metal Rooftop Installation

Tamil Nadu,  Hosur

Solar Power Plants In Tamilnadu in India
Project size: 1,000 kWp
Roof type: Metal Rooftop
Module type: Polycrystalline
Inverter type: Central inverters
Industry type: Manufacturing
Commissioned on: 2015
CO2 abated annually: 1,440 Tonnes
Equivalent to planting: 23,811 trees
View Photos

1,000 kWp, Metal Rooftop Installation

Tamil Nadu,  Chennai

Solar Power Plants In Tamilnadu in India
Project size: 265 kWp
Roof type: Metal Rooftop
Module type: Polycrystalline
Inverter type: String inverters
Industry type: Auto & Auto ancillaries
Commissioned on: 2015
CO2 abated annually: 382 Tonnes
Equivalent to planting: 6,310 trees
View Photos

265 kWp, Metal Rooftop Installation

Tamil Nadu,  Hosur

Project size: 500 kWp
Roof type: Ground Mount
Module type: Polycrystalline
Inverter type: String inverters
Industry type: Food & Beverage
Commissioned on: 2015
CO2 abated annually: 720 Tonnes
Equivalent to planting: 11,905 trees
View Photos

500 kWp, Ground Mount Installation

Tamil Nadu,  Theni

Solar Power Plants In Tamilnadu in India
Project size: 250 kWp
Roof type: RCC Rooftop
Module type: Polycrystalline
Inverter type: String
Industry type: IT/ITES
Commissioned on: 2014
CO2 abated annually: 360 Tonnes
Equivalent to planting: 5,953 trees
View Photos

250 kWp, RCC Rooftop Installation

Tamil Nadu,  Chennai

Rooftop State Level Policy Data

State Pages on Website Eligibility Criteria for Net Metering i.e. Upper cap and Lower cap Banking Norms for Rooftop Key Approvals required for Rooftop DISCOMs   Key Regulatory Charges/exemptions for Rooftop (if any) For more details visit individual DISCOM website.
Maharashtra 1 kW–1 MW Yearly 1. CEIG approval
2. The consumer and the DISCOM will enter into a Net Metering Connection Agreement, which shall remain in force for 20 years, in the prescribed format after the roof-top solar PV system is installed but before it is synchronized with the distribution network
The rooftop solar system installed on eligible consumer premises, are exempt from payment of banking and wheeling charges and losses, cross subsidy and additional surcharge etc. Project wise Statutory fees, testing fees, supervision charges, application fees etc. are applicable and varies time to time as policy changes
Uttar Pradesh 1 kW–2 MW Yearly 1. CEIG approval
2. No net metering
Rooftop solar PV system under gross metering scheme / net metering scheme, whether self-owned or third party owned and installed on eligible consumer premises are exempt from payment of wheeling and cross subsidy surcharge.
Rajasthan 1 kW–1 MW Yearly 1. CEIG approval
2. Any eligible consumer under the Rajasthan Net Metering Regulations may obtain approval for installation of rooftop solar system on its premises under net metering arrangement in accordance with the Rajasthan Net Metering Regulations and execution of an interconnection agreement for net metering with the distribution licensee.
Rooftop PV solar power plants under net metering arrangement are exempt from payment of wheeling, banking and cross subsidy surcharges.
Karnataka 1 kW–1 MW Monthly 1. CEIG approval (Applicable above 1MW)
2. Net metering approval (if applicable up to 1 MW)
Transmission and wheeling charges will not be applicable to rooftop solar projects to the extent there is no wheeling of such electricity. In case it is a ground mount project then banking and wheeling charges may be applicable
Haryana NA–1 MW Yearly 1. CEIG approval
2. Net metering approval (if applicable) or a ‘no-objection certificate’ from the applicable local distribution utility. The consumer and the distribution utility will enter into a Net Metering Connection Agreement in the prescribed format after the roof-top solar PV system is installed but before it is synchronized with the distribution network.
While the Haryana Solar Policy has waived electricity taxes, electricity cess, electricity duty, and cross subsidy charges etc., but Transmission, wheeling and banking charges may be applicable as per the guidelines and orders issued by the HERC from time to time.
Tamil Nadu Consumers under Low Tension category except Hut and Agricultural category of tariff Yearly

1. CEIG approval
2. Net metering approval (if applicable) or NOC from Tangedco
3. Ministry clearance
4. Reverse test report (RTR) from local Tangedco

Transmission and wheeling charges will not be applicable to rooftop solar projects to the extent there is no wheeling of such electricity.
Delhi 1 kW – NA* Yearly 1. CEIG approval
2. Net metering approval (if applicable) or NOC from DISCOM
In order to promote the third party owned systems and avoid complexities around evaluation and monitoring of wheeling/banking/open access charges, the net metering rooftop solar arrangements are specifically exempted from these charges
Telangana 1 kW–1 MW Half-yearly 1. CEIG Approval
2. The Net metering connection agreement has to be executed by the Consumer with the DISCOM within 15 days of receipt of the technical feasibility approval
3. On inspection of the equipment SPV system are to be synchronized within 10 working days, provided the systems are installed as per the norms and standards
1. Tariff payable by the DISCOM is the APCC of the DISCOM
2. Exempted from transmission charges, transmission loss, wheeling charge, wheeling loss, cross subsidy surcharge and additional surcharge
3. The CDM benefits shall be retained by the consumer for the first year and second year onwards, 10%, progressively increasing by 10% each year till the benefits are shared in equal proportion
Gujarat 1 kW–1 MW Yearly 1. CEIG approval
2. Net metering approval (OPEX project not allowed under net metering regulation. Only CAPEX projects considered for net metering) or NOC from DISCOM
Project wise Statutory fees, testing fees, supervision charges, application fees etc. are applicable and varies time to time as policy changes
Andhra Pradesh 1 kW–1 MW Quarterly 1. CEIG approval
2. Net metering approval (if applicable) or NOC from DISCOM
No Distribution losses and charges will be collected from the Eligible Developers /Group /Society /Individuals by the DISCOMs. All other charges shall be applicable as per the Tariff Order amended from time to time.
West Bengal 5 kW–not specified Yearly 1. CEIG approval
2. Net metering approval (if applicable) or NOC from DISCOM
Transmission and wheeling charges will not be applicable to rooftop solar projects to the extent there is no wheeling of such electricity.
Puducherry NA–500 kWp; Yearly 1. CEA (Central electrical authority) approval
2. Net metering approval (if applicable)
Transmission and wheeling charges will not be applicable to rooftop solar projects to the extent there is no wheeling of such electricity

Eligibility Criteria for Net Metering i.e. Upper cap and Lower cap

1 kW–1 MW

Banking Norms for Rooftop

Yearly

Key Approvals required for Rooftop

  1. CEIG approval
  2. The consumer and the DISCOM will enter into a Net Metering Connection Agreement, which shall remain in force for 20 years, in the prescribed format after the roof-top solar PV system is installed but before it is synchronized with the distribution network

Key Regulatory Charges/exemptions for Rooftop (if any) For more details visit individual DISCOM website.

The rooftop solar system installed on eligible consumer premises, are exempt from payment of banking and wheeling charges and losses, cross subsidy and additional surcharge etc. Project wise Statutory fees, testing fees, supervision charges, application fees etc. are applicable and varies time to time as policy changes

Eligibility Criteria for Net Metering i.e. Upper cap and Lower cap

1 kW–2 MW

Banking Norms for Rooftop

Yearly

Key Approvals required for Rooftop

  1. CEIG approval
  2. No net metering

Key Regulatory Charges/exemptions for Rooftop (if any) For more details visit individual DISCOM website.

Rooftop solar PV system under gross metering scheme / net metering scheme, whether self-owned or third party owned and installed on eligible consumer premises are exempt from payment of wheeling and cross subsidy surcharge.

Eligibility Criteria for Net Metering i.e. Upper cap and Lower cap

1 kW–1 MW

Banking Norms for Rooftop

Yearly

Key Approvals required for Rooftop

  1. CEIG approval
  2. Any eligible consumer under the Rajasthan Net Metering Regulations may obtain approval for installation of rooftop solar system on its premises under net metering arrangement in accordance with the Rajasthan Net Metering Regulations and execution of an interconnection agreement for net metering with the distribution licensee.

Key Regulatory Charges/exemptions for Rooftop (if any) For more details visit individual DISCOM website.

Rooftop PV solar power plants under net metering arrangement are exempt from payment of wheeling, banking and cross subsidy surcharges.

Eligibility Criteria for Net Metering i.e. Upper cap and Lower cap

1 kW–1 MW

Banking Norms for Rooftop

Yearly

Key Approvals required for Rooftop

  1. CEIG approval (Applicable above 1MW)
  2. Net metering approval (if applicable up to 1 MW)

Key Regulatory Charges/exemptions for Rooftop (if any) For more details visit individual DISCOM website.

Transmission and wheeling charges will not be applicable to rooftop solar projects to the extent there is no wheeling of such electricity. In case it is a ground mount project then banking and wheeling charges may be applicable

Eligibility Criteria for Net Metering i.e. Upper cap and Lower cap

NA–1 MW

Banking Norms for Rooftop

Yearly

Key Approvals required for Rooftop

  1. CEIG approval
  2. Net metering approval (if applicable) or a ‘no-objection certificate’ from the applicable local distribution utility.The consumer and the distribution utility will enter into a Net Metering Connection Agreement in the prescribed format after the roof-top solar PV system is installed but before it is synchronized with the distribution network.

Key Regulatory Charges/exemptions for Rooftop (if any) For more details visit individual DISCOM website.

While the Haryana Solar Policy has waived electricity taxes, electricity cess, electricity duty, and cross subsidy charges etc., but Transmission, wheeling and banking charges may be applicable as per the guidelines and orders issued by the HERC from time to time.

Eligibility Criteria for Net Metering i.e. Upper cap and Lower cap

Consumers under Low Tension category except Hut and Agricultural category of tariff

Banking Norms for Rooftop

Yearly

Key Approvals required for Rooftop

  1. CEIG approval
  2. Net metering approval (if applicable) or NOC from Tangedco
  3. Ministry clearance
  4. Reverse test report (RTR) from local Tangedco

Key Regulatory Charges/exemptions for Rooftop (if any) For more details visit individual DISCOM website.

Transmission and wheeling charges will not be applicable to rooftop solar projects to the extent there is no wheeling of such electricity.

Eligibility Criteria for Net Metering i.e. Upper cap and Lower cap

1 kW – NA*

Banking Norms for Rooftop

Yearly

Key Approvals required for Rooftop

  1. CEIG approval
  2. Net metering approval (if applicable) or NOC from DISCOM

Key Regulatory Charges/exemptions for Rooftop (if any) For more details visit individual DISCOM website.

In order to promote the third party owned systems and avoid complexities around evaluation and monitoring of wheeling/banking/open access charges, the net metering rooftop solar arrangements are specifically exempted from these charges

Eligibility Criteria for Net Metering i.e. Upper cap and Lower cap

1 kW–1 MW

Banking Norms for Rooftop

Half-yearly

Key Approvals required for Rooftop

  1. CEIG approval
  2. The Net metering connection agreement has to be executed by the Consumer with the DISCOM within 15 days of receipt of the technical feasibility approval
  3. On inspection of the equipment SPV system are to be synchronized within 10 working days, provided the systems are installed as per the norms and standards

Key Regulatory Charges/exemptions for Rooftop (if any) For more details visit individual DISCOM website.

  1. Tariff payable by the DISCOM is the APCC of the DISCOM
  2. Exempted from transmission charges, transmission loss, wheeling charge, wheeling loss, cross subsidy surcharge and additional surcharge
  3. The CDM benefits shall be retained by the consumer for the first year and second year onwards, 10%, progressively increasing by 10% each year till the benefits are shared in equal proportion

Eligibility Criteria for Net Metering i.e. Upper cap and Lower cap

1 kW–1 MW

Banking Norms for Rooftop

Yearly

Key Approvals required for Rooftop

  1. CEIG approval
  2. Net metering approval (OPEX project not allowed under net metering regulation. Only CAPEX projects considered for net metering) or NOC from DISCOM

Key Regulatory Charges/exemptions for Rooftop (if any) For more details visit individual DISCOM website.

Project wise Statutory fees, testing fees, supervision charges, application fees etc. are applicable and varies time to time as policy changes

Eligibility Criteria for Net Metering i.e. Upper cap and Lower cap

1 kW–1 MW

Banking Norms for Rooftop

Quarterly

Key Approvals required for Rooftop

  1. CEIG approval
  2. Net metering approval (if applicable) or NOC from DISCOM

Key Regulatory Charges/exemptions for Rooftop (if any) For more details visit individual DISCOM website.

No Distribution losses and charges will be collected from the Eligible Developers /Group /Society /Individuals by the DISCOMs. All other charges shall be applicable as per the Tariff Order amended from time to time.

Eligibility Criteria for Net Metering i.e. Upper cap and Lower cap

5 kW–not specified

Banking Norms for Rooftop

Yearly

Key Approvals required for Rooftop

  1. CEIG approval
  2. Net metering approval (if applicable) or NOC from DISCOM

Key Regulatory Charges/exemptions for Rooftop (if any) For more details visit individual DISCOM website.

Transmission and wheeling charges will not be applicable to rooftop solar projects to the extent there is no wheeling of such electricity.

Eligibility Criteria for Net Metering i.e. Upper cap and Lower cap

NA–500 kWp;

Banking Norms for Rooftop

Yearly

Key Approvals required for Rooftop

  1. CEA (Central electrical authority) approval
  2. Net metering approval (if applicable)

Key Regulatory Charges/exemptions for Rooftop (if any) For more details visit individual DISCOM website.

Transmission and wheeling charges will not be applicable to rooftop solar projects to the extent there is no wheeling of such electricity



* Subject to
- feasibility of interconnection with grid
- available capacity of service line connection of consumer of premise
- the sanctioned load of consumer of the premise

Source: Centre for Energy Finance, Individual DISCOM websites

Disclaimer: The information presented above is for educational purposes only. All the data provided in the article above are approximate values derived from third party sources, research articles or on ground experience and CleanMax would take no responsibility or have any obligation over the correctness of data. The regulatory policies get updated from time to time and it is highly encouraged that you head over to individual DISCOM sites to refer the latest changes.


Acronyms Used:

NOC No Objection Certificate
HERC Haryana Electricity Regulatory Commission
APPC Average Power Purchase Cost
CEIG Chief Electrical Inspector to Government
CDM Clean Development Mechanism